Permeate flow: 13.200 gpd Mgso4
Stable Salt Rejection: ≥90%(MgSO4)
Configuration: Spiral Wound
Membrane Polymer: Composite Polyamide
Membrane Active Area:400 ft (37 m²)
Maximum Applied Pressure: 600PSI(4.13MPa)
Maximum Chlorine Concentration: <
0.1 PPM
Maximum Operating Temperature: 113 °F ( 45°c)
pH Range, Continuous (Cleaning): 3-10 (2-12)
Maximum Feed Silt Density Index: SDI 5
The stated performance is initial (data taken after 12-24 hours of operation), based on the following conditions.
2000 ppm MgSO4 Solution
70 psi(0.48 MPa) Applied Pressure
77°℉ (25°C) Operating Temperature
15% Permeate Recovery
8 pH Range